DRV.FAULTHIST
General Information
Type R/O Parameter
Description Reads the last 10 faults from NV memory.
Units N/A
Range N/A
Default Value N/A
Data Type N/A
See Also DRV.FAULTS, DRV.CLRFAULTHIST
Start Version M_01-00-00-000
Description
DRV.FAULTHISTORYreturnsthelast50faultsthatoccurredinthedrive.Thefaultsareshownwiththeirfaultnumber
(whichmatchestheonedisplayedonthedrivedisplay)andatimestampthatindicateswhentheylastoccurred.
Issue a DRV.CLRFAULTHIST to clear this fault log.
AKD User Guide | DRV Parameters and Commands
Kollmorgen | December 2010 365

Table of Contents

Other manuals for Kollmorgen AKD series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kollmorgen AKD series and is the answer not in the manual?

Kollmorgen AKD series Specifications

General IconGeneral
Continuous CurrentUp to 180 A
Control ModesPosition, Velocity, Torque
Communication InterfacesEtherCAT, CANopen, Modbus TCP/IP
Feedback OptionsResolver, Encoder
Safety FeaturesSafe Torque Off (STO), Safe Stop 1 (SS1)
Protection FeaturesOvervoltage, Undervoltage, Overcurrent, Short Circuit, Overtemperature
Switching Frequency8 kHz, 16 kHz
Ambient Temperature0°C to 40°C
Operating Temperature0 - 40 °C (derating may apply)
Humidity5% to 95% non-condensing