DRV.ICONT
General Information
Type R/O Parameter
Description Reads the continuous rated current value.
Units Arms
Range N/A
Default Value N/A
Data Type Float
See Also DRV.IPEAK
Start Version M_01-00-00-000
Fieldbus Index/Subindex Object Start Version
Modbus 262 M_01-03-00-000
Description
DRV.ICONT returns the drive continuous rated current in Arms.
The value of the continuous current is read automatically on drive boot from the power EEPROM of the drive.
This value cannot be modified.
AKD User Guide | DRV Parameters and Commands
Kollmorgen | December 2010 371