AKD User Guide | DOUT Parameters
DOUT.RELAYMODE
General Information
Type R/W Parameter
Description Indicates faults relay mode.
Units N/A
Range 0 to 1
Default Value 0
Data Type Boolean
See Also N/A
Start Version M_01-00-00-000
Fieldbus Index/Subindex Object Start Version
Modbus 192 M_01-03-00-000
Description
DOUT.RELAYMODE indicates the faults relay mode as follows:
If DOUT.RELAYMODE= 0 and faults exist, then the relay is open.
If DOUT.RELAYMODE= 0 and faults do not exist, then the relay is closed.
If DOUT.RELAYMODE = 1 and the drive is disabled, then the relay is open.
If DOUT.RELAYMODE = 1 and the drive is enabled, then the relay is closed.
Related Topics
10.1.4 Digital Outputs
334 Kollmorgen | December 2010

Table of Contents

Other manuals for Kollmorgen AKD series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kollmorgen AKD series and is the answer not in the manual?

Kollmorgen AKD series Specifications

General IconGeneral
Continuous CurrentUp to 180 A
Control ModesPosition, Velocity, Torque
Communication InterfacesEtherCAT, CANopen, Modbus TCP/IP
Feedback OptionsResolver, Encoder
Safety FeaturesSafe Torque Off (STO), Safe Stop 1 (SS1)
Protection FeaturesOvervoltage, Undervoltage, Overcurrent, Short Circuit, Overtemperature
Switching Frequency8 kHz, 16 kHz
Ambient Temperature0°C to 40°C
Operating Temperature0 - 40 °C (derating may apply)
Humidity5% to 95% non-condensing

Related product manuals