VL.BUSFF
General Information
Type R/O Parameter
Description
Displays the velocity loop feedforward value injected by the field-bus;
active in opmodes 1 (velocity) and 2 (position) only.
Units
Depends on UNIT.VROTARY or UNIT.VLINEARUNIT.ACCLINEAR
Rotary: rpm, rps, deg/s, (PIN/POUT)/s, rad/s
Linear: counts/s, mm/s, µm/s, (PIN/POUT)/s
Range 0.0 to VL.LIMITP
Default Value 0.0
Data Type Float
See Also VL.FF, VL.KBUSFF
Start Version M_01-00-00-000
Fieldbus Index/Subindex Object Start Version
EtherCAT COE
and CANopen
60B1h/0 M_01-00-00-000
Modbus 848 M_01-03-00-000
Description
This parameter displays the velocity loop feedforward value injected by the fieldbus.
Related Topics
11.4 Velocity Loop
AKD User Guide | VL Parameters
Kollmorgen | December 2010 629

Table of Contents

Other manuals for Kollmorgen AKD series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kollmorgen AKD series and is the answer not in the manual?

Kollmorgen AKD series Specifications

General IconGeneral
Continuous CurrentUp to 180 A
Control ModesPosition, Velocity, Torque
Communication InterfacesEtherCAT, CANopen, Modbus TCP/IP
Feedback OptionsResolver, Encoder
Safety FeaturesSafe Torque Off (STO), Safe Stop 1 (SS1)
Protection FeaturesOvervoltage, Undervoltage, Overcurrent, Short Circuit, Overtemperature
Switching Frequency8 kHz, 16 kHz
Ambient Temperature0°C to 40°C
Operating Temperature0 - 40 °C (derating may apply)
Humidity5% to 95% non-condensing