EasyManua.ls Logo

Kollmorgen AKD series

Kollmorgen AKD series
906 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
AKD User Guide | DRV Parameters and Commands
DRV.TEMPERATURES
General Information
Type R/O Parameter
Description Reads the temperature of drive components.
Units °C
Range 55 to 125 °C
Default Value N/A
Data Type String
See Also N/A
Start Version M_01-00-00-000
Fieldbus Index/Subindex Object Start Version
EtherCAT COE
and CANopen
3610h/0
3611h/0
M_01-00-00-000
Modbus N/A M_01-03-00-000
Description
DRV.TEMPERATURES reads the temperature in different parts of the drive (power and control boards). The tem-
perature is read from temperature sensors located in the drive.
Example
Below is an example of the output for this command :
Control Temperature: 39 °C
Power1 Temperature: 31 °C
Power2 Temperature: Sensor does not exist.
Power3 Temperature: Sensor does not exist.
392 Kollmorgen | December 2010

Table of Contents

Other manuals for Kollmorgen AKD series

Related product manuals