REC.TRIGSLOPE
General Information
Type R/W Parameter
Description Sets the trigger slope.
Units
0 = Negative
1 = Positive
Range 0 to 1
Default Value 0
Data Type Boolean
See Also REC.TRIG, REC.NUMPOINTS
Start Version M_01-00-00-000
Fieldbus Index/Subindex Object Start Version
Modbus 726 M_01-03-00-000
Description
REC.TRIGSLOPE sets the recorder trigger slope. This parameter is only used when REC.TRIGTYPE = 2 or 3.