MOTOR Parameters
MOTOR.AUTOSET
General Information
Type NV Parameter
Description Determines which drive parameters are calculated automatically.
Units N/A
Range 0 to 1
Default Value 0
Data Type Boolean
See Also N/A
Start Version M_01-00-00-000
Fieldbus Index/Subindex Object Start Version
EtherCAT COE
and CANopen
3451h/0 M_01-00-00-000
Modbus 480 M_01-03-00-000
Description
This parameter determines whether or not certain drive parameters (for example, IL.KP or MOTOR.POLES) are
calculated automatically. A value of 1 causes the parameters to be automatically calculated from the motor ID
data (read from memory-supporting feedback devices, such as SFD, Endat, and BISS). Automatically cal-
culated parameters are read-only. A value of 0 disables the automatic calculation and you must set the param-
eters manually. Manually set parameters are read-write.
Related Topics
8.1 Motor
AKD User Guide | MOTOR Parameters
Kollmorgen | December 2010 487