EasyManua.ls Logo

Kollmorgen AKD series

Kollmorgen AKD series
906 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
AKD User Guide | BODE Parameters
BODE.FREQ
General Information
Type R/W Parameter
Description Sets the frequency of the sine excitation source.
Units
Hz
Range 0 to 8,000 Hz
Default Value 0 Hz
Data Type Float
See Also BODE.MODE BODE.INJECTPOINT, BODE.IAMP, BODE.VAMP
Start Version M_01-00-00-000
Fieldbus Index/Subindex Object Start Version
Modbus 40 M_01-03-00-000
Description
BODE.FREQ sets the frequency of the sine excitation source in Hz. The sine excitation source is used to take
frequency response measurements of a system.
Example
Setting up a sine excitation source of 0.2 A at 50 Hz:
-->BODE.INJECTPOINT 1
-->BODE.IAMP 0.2
-->BODE.FREQ 50.0
-->BODE.MODE 2
Related Topics
14.3 Using the Autotuner
14.3.4 Using the Autotuner: Advanced
15 Scope
1.2.1.5 Bode (set command source)
6.5 Settings
126
Error: Invalid Bode plot mode for this function. and others)
292 Kollmorgen | December 2010

Table of Contents

Other manuals for Kollmorgen AKD series

Related product manuals