MOTOR.POLES
General Information
Type NV Parameter
Description Sets the number of motor poles.
Units N/A
Range 0 to 128
Default Value 6
Data Type Integer
See Also FB1.POLES
Start Version M_01-00-00-000
Fieldbus Index/Subindex Object Start Version
EtherCAT COE
and CANopen
359Dh/0 M_01-00-00-000
Modbus 504 M_01-03-00-000
Description
MOTOR.POLES sets the number of motor poles.This command is used for commutation control and represents
the number of individual magnetic poles of the motor (not pole pairs). The division value of motor poles
(MOTOR.POLES) and feedback poles (FB1.POLES) must be an integer when setting drive to enable, otherwise
a fault is issued.
Related Topics
8.1 Motor
AKD User Guide | MOTOR Parameters
Kollmorgen | December 2010 501