AKD User Guide | PLS Parameters and Commands
PLS.STATE
General Information
Type R/O Parameter
Description Reads the programmable limit switch state.
Units N/A
Range N/A
Default Value N/A
Data Type Integer
See Also
PLS.EN, PLS.RESET, PLS.UNITS, PLS.MODE, PLS.P1 TO PLS.P8,
PLS.WIDTH1 TO PLS.WIDTH8, PLS.T1 TOPLS.T8
Start Version M_01-02-03-000
Fieldbus Index/Subindex Object Start Version
EtherCAT COE
and CANopen
34A3h/4 M_01-02-03-000
Modbus 656 M_01-03-00-000
Description
This parameter is a bit variable and displays the current status of the individual programmable limit switches.
Example
Bit 0 = 0: Programmable Limit Switch 1 (PLS 1) is not active.
Bit 0 = 1: Programmable Limit Switch 1 (PLS 1) is active.
Bit 7 = 0: Programmable Limit Switch 8 (PLS 8) is not active.
Bit 7 = 1: Programmable Limit Switch 8 (PLS 8) is not active.
Related Topics
10.8 Programmable Limit Switch
558 Kollmorgen | December 2010

Table of Contents

Other manuals for Kollmorgen AKD series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kollmorgen AKD series and is the answer not in the manual?

Kollmorgen AKD series Specifications

General IconGeneral
Continuous CurrentUp to 180 A
Control ModesPosition, Velocity, Torque
Communication InterfacesEtherCAT, CANopen, Modbus TCP/IP
Feedback OptionsResolver, Encoder
Safety FeaturesSafe Torque Off (STO), Safe Stop 1 (SS1)
Protection FeaturesOvervoltage, Undervoltage, Overcurrent, Short Circuit, Overtemperature
Switching Frequency8 kHz, 16 kHz
Ambient Temperature0°C to 40°C
Operating Temperature0 - 40 °C (derating may apply)
Humidity5% to 95% non-condensing

Related product manuals