AKD User Guide | DRV Parameters and Commands
DRV.EMUEZOFFSET
General Information
Type R/W Parameter
Description
Sets the location of the EEO (emulated encoder output) index pulse (when
DRV.EMUEMODE=1).
Units 1/65536 rev
Range 0 to 65535 rev
Default Value 0 rev
Data Type Integer
See Also DRV.EMUEMODE, DRV.EMUEMTURN
Start Version M_01-00-00-000
Fieldbus Index/Subindex Object Start Version
EtherCAT COE
and CANopen
3537h/0 M_01-00-00-000
Modbus 252 M_01-03-00-000
Description
When EEO multiturn is selected (DRV.EMUEMODE=1), this parameter sets a position of the EEO index. When
the primary feedback position (within a revolution) equals this value, an index pulse will output.
Related Topics
8.4.1 Encoder Emulation
362 Kollmorgen | December 2010

Table of Contents

Other manuals for Kollmorgen AKD series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kollmorgen AKD series and is the answer not in the manual?

Kollmorgen AKD series Specifications

General IconGeneral
Continuous CurrentUp to 180 A
Control ModesPosition, Velocity, Torque
Communication InterfacesEtherCAT, CANopen, Modbus TCP/IP
Feedback OptionsResolver, Encoder
Safety FeaturesSafe Torque Off (STO), Safe Stop 1 (SS1)
Protection FeaturesOvervoltage, Undervoltage, Overcurrent, Short Circuit, Overtemperature
Switching Frequency8 kHz, 16 kHz
Ambient Temperature0°C to 40°C
Operating Temperature0 - 40 °C (derating may apply)
Humidity5% to 95% non-condensing