EasyManuals Logo

Kollmorgen AKD series User Manual

Kollmorgen AKD series
906 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #474 background imageLoading...
Page #474 background image
AKD User Guide | IL Parameters
IL.KP
General Information
Type NV Parameter
Description Sets the proportional gain of the q-component of the PI regulator.
Units V/A
Range 0 to 2,000 V/A
Default Value Read from the motor or, if no memory, 50.009 V/A
Data Type Float
See Also N/A
Start Version M_01-00-00-000
Fieldbus Index/Subindex Object Start Version
EtherCAT COE
and CANopen
3598h/0 M_01-00-00-000
Modbus 454 M_01-03-00-000
Description
IL.KP is used to modify the proportional gain of the PI-loop that controls the q-component of the current.
Related Topics
11.3 Current Loop
474 Kollmorgen | December 2010

Table of Contents

Other manuals for Kollmorgen AKD series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kollmorgen AKD series and is the answer not in the manual?

Kollmorgen AKD series Specifications

General IconGeneral
Continuous CurrentUp to 180 A
Control ModesPosition, Velocity, Torque
Communication InterfacesEtherCAT, CANopen, Modbus TCP/IP
Feedback OptionsResolver, Encoder
Safety FeaturesSafe Torque Off (STO), Safe Stop 1 (SS1)
Protection FeaturesOvervoltage, Undervoltage, Overcurrent, Short Circuit, Overtemperature
Switching Frequency8 kHz, 16 kHz
Ambient Temperature0°C to 40°C
Operating Temperature0 - 40 °C (derating may apply)
Humidity5% to 95% non-condensing

Related product manuals