EasyManuals Logo

Kollmorgen AKD series User Manual

Kollmorgen AKD series
906 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #477 background imageLoading...
Page #477 background image
IL.LIMITN
General Information
Type NV Parameter
Description Sets the negative user (application-specific) current limit.
Units A
Range Negative drive peak current (DRV.IPEAK) to 0 A
Default Value Negative drive peak current (DRV.IPEAK)
Data Type Float
See Also IL.LIMITP
Start Version M_01-00-00-000
Fieldbus Index/Subindex Object Start Version
EtherCAT COE
and CANopen
356Fh/0 M_01-00-00-000
Modbus 460 M_01-03-00-000
Description
This parameter sets the negative user limit clamp value of the torqueproducing q-component current command
(IL.CMD ). The current command is additionally limited by the motor peak current setting (MOTOR.IPEAK) and
by the present value of the foldback I²t peak motor current protection.
Related Topics
11.3 Current Loop
AKD User Guide | IL Parameters
Kollmorgen | December 2010 477

Table of Contents

Other manuals for Kollmorgen AKD series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kollmorgen AKD series and is the answer not in the manual?

Kollmorgen AKD series Specifications

General IconGeneral
Continuous CurrentUp to 180 A
Control ModesPosition, Velocity, Torque
Communication InterfacesEtherCAT, CANopen, Modbus TCP/IP
Feedback OptionsResolver, Encoder
Safety FeaturesSafe Torque Off (STO), Safe Stop 1 (SS1)
Protection FeaturesOvervoltage, Undervoltage, Overcurrent, Short Circuit, Overtemperature
Switching Frequency8 kHz, 16 kHz
Ambient Temperature0°C to 40°C
Operating Temperature0 - 40 °C (derating may apply)
Humidity5% to 95% non-condensing