EasyManua.ls Logo

Kollmorgen AKD series

Kollmorgen AKD series
906 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
DIN1.INV TO DIN7.INV
General Information
Type R/W Parameter
Description Sets the indicated the polarity of a digital input mode.
Units N/A
Range 0 to 1
Default Value 0
Data Type Boolean
See Also N/A
Start Version M_01-00-00-000
Fieldbus Index/Subindex Object Start Version
Modbus
120 DIN1.INV
130 DIN2.INV
140 DIN3.INV
150 DIN4.INV
160 DIN5.INV
170 DIN6.INV
180 DIN7.INV
M_01-03-00-000
Description
Sets the indicated the polarity of a digital input mode.
Example
DIN1.INV = 0 : Input is active high.
DIN1.INV = 1 : Input is active low.
Related Topics
10.1 Digital Inputs and Outputs
AKD User Guide | DIN Parameters
Kollmorgen | December 2010 327

Table of Contents

Other manuals for Kollmorgen AKD series

Related product manuals