DIN1.INV TO DIN7.INV
General Information
Type R/W Parameter
Description Sets the indicated the polarity of a digital input mode.
Units N/A
Range 0 to 1
Default Value 0
Data Type Boolean
See Also N/A
Start Version M_01-00-00-000
Fieldbus Index/Subindex Object Start Version
Modbus
120 DIN1.INV
130 DIN2.INV
140 DIN3.INV
150 DIN4.INV
160 DIN5.INV
170 DIN6.INV
180 DIN7.INV
M_01-03-00-000
Description
Sets the indicated the polarity of a digital input mode.
Example
DIN1.INV = 0 : Input is active high.
DIN1.INV = 1 : Input is active low.
Related Topics
10.1 Digital Inputs and Outputs
AKD User Guide | DIN Parameters
Kollmorgen | December 2010 327

Table of Contents

Other manuals for Kollmorgen AKD series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kollmorgen AKD series and is the answer not in the manual?

Kollmorgen AKD series Specifications

General IconGeneral
Continuous CurrentUp to 180 A
Control ModesPosition, Velocity, Torque
Communication InterfacesEtherCAT, CANopen, Modbus TCP/IP
Feedback OptionsResolver, Encoder
Safety FeaturesSafe Torque Off (STO), Safe Stop 1 (SS1)
Protection FeaturesOvervoltage, Undervoltage, Overcurrent, Short Circuit, Overtemperature
Switching Frequency8 kHz, 16 kHz
Ambient Temperature0°C to 40°C
Operating Temperature0 - 40 °C (derating may apply)
Humidity5% to 95% non-condensing