AKD User Guide | IL Parameters
IL.FOLDFTHRESHU
General Information
Type NV Parameter
Description Sets the user value for the foldback fault level.
Units Arms
Range 0 to 500 Arms
Default Value Drive peak current (DRV.IPEAK)
Data Type Float
See Also IL.FOLDFTHRESH, Foldback
Start Version M_01-00-00-000
Fieldbus Index/Subindex Object Start Version
EtherCAT COE
and CANopen
3421h/0 M_01-00-00-000
Modbus 438 M_01-03-00-000
Description
IL.FOLDFTHRESHU is the fault level of the current foldback algorithm. The value of IL.FOLDFTHRESH is the
minimum of DRV.IPEAK, MOTOR.IPEAK, and IL.FOLDFTHRESHU.
Related Topics
11.3 Current Loop
466 Kollmorgen | December 2010