AKD User Guide | MOTOR Parameters
MOTOR.TEMPWARN
General Information
Type NV Parameter
Description Sets the motor temperature warning level.
Units
Range 0 to 2,000,000,000
Default Value 0 = switched off
Data Type Integer
See Also MOTOR.TEMP
Start Version M_01-00-00-000
Fieldbus Index/Subindex Object Start Version
EtherCAT COE
and CANopen
3453h/0 M_01-00-00-000
Modbus 518 M_01-03-00-000
Description
This parameter is used to configure the motor temperature warning level as a resistance threshold of the motor
PTC.
A zero value prevents any warning from being created.