AKD User Guide | MOTOR Parameters
MOTOR.TEMPWARN
General Information
Type NV Parameter
Description Sets the motor temperature warning level.
Units
Range 0 to 2,000,000,000
Default Value 0 = switched off
Data Type Integer
See Also MOTOR.TEMP
Start Version M_01-00-00-000
Fieldbus Index/Subindex Object Start Version
EtherCAT COE
and CANopen
3453h/0 M_01-00-00-000
Modbus 518 M_01-03-00-000
Description
This parameter is used to configure the motor temperature warning level as a resistance threshold of the motor
PTC.
A zero value prevents any warning from being created.
Related Topics
8.1 Motor
508 Kollmorgen | December 2010

Table of Contents

Other manuals for Kollmorgen AKD series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kollmorgen AKD series and is the answer not in the manual?

Kollmorgen AKD series Specifications

General IconGeneral
Continuous CurrentUp to 180 A
Control ModesPosition, Velocity, Torque
Communication InterfacesEtherCAT, CANopen, Modbus TCP/IP
Feedback OptionsResolver, Encoder
Safety FeaturesSafe Torque Off (STO), Safe Stop 1 (SS1)
Protection FeaturesOvervoltage, Undervoltage, Overcurrent, Short Circuit, Overtemperature
Switching Frequency8 kHz, 16 kHz
Ambient Temperature0°C to 40°C
Operating Temperature0 - 40 °C (derating may apply)
Humidity5% to 95% non-condensing