REC.STOPTYPE
General Information
Type R/W Parameter
Description Sets the recorder stop type.
Units N/A
Range 0 or 1
Default Value 0
Data Type Integer
See Also REC.RETRIEVEDATA, REC.RETRIEVESIZE
Start Version M_01-00-00-000
Fieldbus Index/Subindex Object Start Version
Modbus 718 M_01-03-00-000
Description
This parameter sets the stop type for the recording.
0 = Recorder runs, continuously filling the recording circular buffer.
1 = Recorder fills in the buffer once.
To stop RT recording, execute REC.OFF.
Related Topics
15 Scope
AKD User Guide | REC Parameters and Commands
Kollmorgen | December 2010 575

Table of Contents

Other manuals for Kollmorgen AKD series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kollmorgen AKD series and is the answer not in the manual?

Kollmorgen AKD series Specifications

General IconGeneral
Continuous CurrentUp to 180 A
Control ModesPosition, Velocity, Torque
Communication InterfacesEtherCAT, CANopen, Modbus TCP/IP
Feedback OptionsResolver, Encoder
Safety FeaturesSafe Torque Off (STO), Safe Stop 1 (SS1)
Protection FeaturesOvervoltage, Undervoltage, Overcurrent, Short Circuit, Overtemperature
Switching Frequency8 kHz, 16 kHz
Ambient Temperature0°C to 40°C
Operating Temperature0 - 40 °C (derating may apply)
Humidity5% to 95% non-condensing