VBUS.UVFTHRESH
General Information
Type R/W Parameter
Description Sets the under voltage fault level.
Units Vdc
Range 90 to 420 Vdc
Default Value 90 Vdc
Data Type Integer
See Also VBUS.OVFTHRESH
Start Version M_01-00-00-000
Fieldbus Index/Subindex Object Start Version
Modbus 800 M_01-03-00-000
Description
VBUS.UVFTHRESH sets the undervoltage fault level of the DC bus.
The default value is read from the EEPROM, but can by modified by the user and stored on the NV RAM. This
value varies according to drive type.
Related Topics
7.2 Regeneration
AKD User Guide | VBUS Parameters
Kollmorgen | December 2010 617

Table of Contents

Other manuals for Kollmorgen AKD series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kollmorgen AKD series and is the answer not in the manual?

Kollmorgen AKD series Specifications

General IconGeneral
Continuous CurrentUp to 180 A
Control ModesPosition, Velocity, Torque
Communication InterfacesEtherCAT, CANopen, Modbus TCP/IP
Feedback OptionsResolver, Encoder
Safety FeaturesSafe Torque Off (STO), Safe Stop 1 (SS1)
Protection FeaturesOvervoltage, Undervoltage, Overcurrent, Short Circuit, Overtemperature
Switching Frequency8 kHz, 16 kHz
Ambient Temperature0°C to 40°C
Operating Temperature0 - 40 °C (derating may apply)
Humidity5% to 95% non-condensing