AKD User Guide | HOME Parameters
HOME.FEEDRATE
General Information
Type R/W Parameter
Description Sets homing velocity factor; active in opmode 2 (position) only.
Units %
Range 0 to 100%
Default Value 50%
Data Type Integer
See Also N/A
Start Version M_01-00-00-000
Fieldbus Index/Subindex Object Start Version
EtherCAT COE
and CANopen
6099h/2 M_01-00-00-000
Modbus 400 M_01-03-00-000
Description
This parameter is used in order to reduce the velocity during the index search (index = zero-pulse of a feedback
device). This parameter determines the percentage of the homing velocity (HOME.V) that should be used during
the index-search.
Related Topics
12.1 Homing
448 Kollmorgen | December 2010

Table of Contents

Other manuals for Kollmorgen AKD series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kollmorgen AKD series and is the answer not in the manual?

Kollmorgen AKD series Specifications

General IconGeneral
Continuous CurrentUp to 180 A
Control ModesPosition, Velocity, Torque
Communication InterfacesEtherCAT, CANopen, Modbus TCP/IP
Feedback OptionsResolver, Encoder
Safety FeaturesSafe Torque Off (STO), Safe Stop 1 (SS1)
Protection FeaturesOvervoltage, Undervoltage, Overcurrent, Short Circuit, Overtemperature
Switching Frequency8 kHz, 16 kHz
Ambient Temperature0°C to 40°C
Operating Temperature0 - 40 °C (derating may apply)
Humidity5% to 95% non-condensing