DOUT Parameters
DOUT.CTRL
General Information
Type NV Parameter
Description Sets the source of digital outputs (firmware or fieldbus).
Units N/A
Range 0 to 1
Default Value 0
Data Type Boolean
See Also N/A
Start Version M_01-00-00-000
Fieldbus Index/Subindex Object Start Version
Modbus 190 M_01-03-00-000
Description
DOUT.CTRL sets the source of the digital outputs:
0 = Firmware controlled
1 = Fieldbus controlled
Related Topics
10.1.4 Digital Outputs
AKD User Guide | DOUT Parameters