EasyManua.ls Logo

Kollmorgen AKD series - MOTOR.ICONT

Kollmorgen AKD series
906 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
AKD User Guide | MOTOR Parameters
MOTOR.ICONT
General Information
Type NV Parameter
Description Sets the motor continuous current.
Units A
Range 0.1 to 500 A
Default Value 1.0 A
Data Type Float
See Also N/A
Start Version M_01-00-00-000
Fieldbus Index/Subindex Object Start Version
EtherCAT COE
and CANopen
358Eh/0 M_01-00-00-000
Modbus 488 M_01-03-00-000
Description
This parameter is used to configure the motor continuous current.
Related Topics
8.1 Motor
MOTOR.IDDATAVALID
General Information
Type R/O Parameter
Description Reports the status of the motor memory.
Units N/A
Range N/A
Default Value 0
Data Type Integer
See Also N/A
Start Version M_01-02-00-000
Fieldbus Index/Subindex Object Start Version
Modbus 490 M_01-03-00-000
Description
MOTOR.IDDATAVALID reports the status of the motor memory status.
The valid values for this keyword are the following:
Value Description
0 Error in identification
1 Success in identification
2 Identification in process
3 Identification not started yet
4
Success recognizing feedback, but failed to varify OEM data
integrity
Related Topics