DRV.RSTVAR
General Information
Type Command
Description
Sets default values in the drive without re-booting the drive and without
resetting the NV memory.
Units N/A
Range N/A
Default Value N/A
Data Type N/A
See Also
Start Version M_01-00-00-000
Fieldbus Index/Subindex Object Start Version
Modbus 272 M_01-03-00-000
Description
DRV.RSTVAR causes the drive to return to the default values without the need to re-boot the drive first and with-
out resetting the NV memory. Use DRV.RSTVAR to return to the default settings and recover a working drive.
AKD User Guide | DRV Parameters and Commands
Kollmorgen | December 2010 387

Table of Contents

Other manuals for Kollmorgen AKD series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kollmorgen AKD series and is the answer not in the manual?

Kollmorgen AKD series Specifications

General IconGeneral
Continuous CurrentUp to 180 A
Control ModesPosition, Velocity, Torque
Communication InterfacesEtherCAT, CANopen, Modbus TCP/IP
Feedback OptionsResolver, Encoder
Safety FeaturesSafe Torque Off (STO), Safe Stop 1 (SS1)
Protection FeaturesOvervoltage, Undervoltage, Overcurrent, Short Circuit, Overtemperature
Switching Frequency8 kHz, 16 kHz
Ambient Temperature0°C to 40°C
Operating Temperature0 - 40 °C (derating may apply)
Humidity5% to 95% non-condensing