General Information
Type NV Parameter
Description
Sets feedback source for the velocity loop; active in opmodes 1 (velocity)
and 2 (position) only.
Units N/A
Range 0 to 1
Default Value 0
Data Type Boolean
See Also PL.FBSOURCE
Start Version M_01-00-00-000
Fieldbus Index/Subindex Object Start Version
Modbus 860 M_01-03-00-000
Description
This parameter determines the feedback source to be used by the velocity loop. A value of 0 selects the primary
feedback, 1 selects the secondary feedback.
Related Topics
11.4 Velocity Loop
AKD User Guide | VL Parameters
Kollmorgen | December 2010 635