VL.FBSOURCE
General Information
Type NV Parameter
Description
Sets feedback source for the velocity loop; active in opmodes 1 (velocity)
and 2 (position) only.
Units N/A
Range 0 to 1
Default Value 0
Data Type Boolean
See Also PL.FBSOURCE
Start Version M_01-00-00-000
Fieldbus Index/Subindex Object Start Version
Modbus 860 M_01-03-00-000
Description
This parameter determines the feedback source to be used by the velocity loop. A value of 0 selects the primary
feedback, 1 selects the secondary feedback.
Related Topics
11.4 Velocity Loop
AKD User Guide | VL Parameters
Kollmorgen | December 2010 635

Table of Contents

Other manuals for Kollmorgen AKD series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kollmorgen AKD series and is the answer not in the manual?

Kollmorgen AKD series Specifications

General IconGeneral
Continuous CurrentUp to 180 A
Control ModesPosition, Velocity, Torque
Communication InterfacesEtherCAT, CANopen, Modbus TCP/IP
Feedback OptionsResolver, Encoder
Safety FeaturesSafe Torque Off (STO), Safe Stop 1 (SS1)
Protection FeaturesOvervoltage, Undervoltage, Overcurrent, Short Circuit, Overtemperature
Switching Frequency8 kHz, 16 kHz
Ambient Temperature0°C to 40°C
Operating Temperature0 - 40 °C (derating may apply)
Humidity5% to 95% non-condensing