AKD User Guide | WS Parameters
WS.TDELAY3
General Information
Type NV Parameter
Description Sets the delay for wake and shake between loops in mode 0.
Units ms
Range 0 to 2,000 ms
Default Value 100 ms
Data Type U16
See Also N/A
Start Version M_01-01-00-102, M_01-02-00-000
Fieldbus Index/Subindex Object Start Version
EtherCAT COE
and CANopen
3494h/3 M_01-00-00-000
Modbus 914 M_01-03-00-000
Description
WS.TDELAY3 defines the delay between complete loops in mode 0 only. Decreasing this value makes the wake
and shake procedure faster, but may lead to problems if the motor moves too long. Increasing this value will
make wake and shake significantly longer.
Related Topics
8.3.9 Using Wake and Shake (WS)
660 Kollmorgen | December 2010

Table of Contents

Other manuals for Kollmorgen AKD series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kollmorgen AKD series and is the answer not in the manual?

Kollmorgen AKD series Specifications

General IconGeneral
Continuous CurrentUp to 180 A
Control ModesPosition, Velocity, Torque
Communication InterfacesEtherCAT, CANopen, Modbus TCP/IP
Feedback OptionsResolver, Encoder
Safety FeaturesSafe Torque Off (STO), Safe Stop 1 (SS1)
Protection FeaturesOvervoltage, Undervoltage, Overcurrent, Short Circuit, Overtemperature
Switching Frequency8 kHz, 16 kHz
Ambient Temperature0°C to 40°C
Operating Temperature0 - 40 °C (derating may apply)