DRV.FAULTS
General Information
Type R/O Parameter
Description Reads the active faults.
Units N/A
Range N/A
Default Value N/A
Data Type N/A
See Also DRV.CLRFAULTS, DRV.FAULTHIST, DRV.CLRFAULTHIST
Start Version M_01-00-00-000
Description
DRV.FAULTS returns a list of all currently active faults in the system, preceded by their fault number which
matches the number displayed on the drive display.
To clear the faults, either issue a DRV.CLRFAULTS or issue a DRV.DIS followed by DRV.EN.
If no active faults are in the system, then after executing DRV.CLRFAULTS the value read by DRV.FAULTS is
"No faults active".
Example
-->DRV.FAULTS
502: Bus under voltage.
-->
366 Kollmorgen | December 2010

Table of Contents

Other manuals for Kollmorgen AKD series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kollmorgen AKD series and is the answer not in the manual?

Kollmorgen AKD series Specifications

General IconGeneral
Continuous CurrentUp to 180 A
Control ModesPosition, Velocity, Torque
Communication InterfacesEtherCAT, CANopen, Modbus TCP/IP
Feedback OptionsResolver, Encoder
Safety FeaturesSafe Torque Off (STO), Safe Stop 1 (SS1)
Protection FeaturesOvervoltage, Undervoltage, Overcurrent, Short Circuit, Overtemperature
Switching Frequency8 kHz, 16 kHz
Ambient Temperature0°C to 40°C
Operating Temperature0 - 40 °C (derating may apply)
Humidity5% to 95% non-condensing