FB2 Parameters
FB2.ENCRES
General Information
Type NV Parameter
Description Sets the secondary feedback (FB2) resolution.
Units counts/rev
Range 0 to 262,140 counts/rev
Default Value 0
Data Type Integer
See Also FB2.MODE, FB2.SOURCE
Start Version M_01-03-00-000
Description
This parameter sets the feedback 2 (FB2) resolution and defines how many counts input into the secondary feed-
back will be considered a full revolution.
Related Topics
8.4 Feedback 2
AKD User Guide | FB2 Parameters
Kollmorgen | December 2010 417