AKD User Guide | VL Parameters
VL.KBUSFF
General Information
Type R/W Parameter
Description
Sets the velocity loop acceleration feedforward gain value; active in
opmodes 1 (velocity) and 2 (position) only.
Units NA
Range 0.0 to 2.0
Default Value 0.0
Data Type Float
See Also VL.BUSFF
Start Version M_01-00-00-000
Fieldbus Index/Subindex Object Start Version
EtherCAT COE
and CANopen
3416h M_01-00-00-000
Modbus 866 M_01-03-00-000
Description
This parameter sets the gain for the acceleration feedforward (a scaled second derivative of the position com-
mand is added to the velocity command value).
The nominal feedforward value can be multiplied by this gain value.
This will have affect only when using position mode (DRV.OPMODE = 2).
Related Topics
11.4 Velocity Loop
638 Kollmorgen | December 2010

Table of Contents

Other manuals for Kollmorgen AKD series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kollmorgen AKD series and is the answer not in the manual?

Kollmorgen AKD series Specifications

General IconGeneral
Continuous CurrentUp to 180 A
Control ModesPosition, Velocity, Torque
Communication InterfacesEtherCAT, CANopen, Modbus TCP/IP
Feedback OptionsResolver, Encoder
Safety FeaturesSafe Torque Off (STO), Safe Stop 1 (SS1)
Protection FeaturesOvervoltage, Undervoltage, Overcurrent, Short Circuit, Overtemperature
Switching Frequency8 kHz, 16 kHz
Ambient Temperature0°C to 40°C
Operating Temperature0 - 40 °C (derating may apply)
Humidity5% to 95% non-condensing