AKD User Guide | REGEN Parameters
REGEN.WATTEXT
General Information
Type R/W parameter
Description Sets the regen resistor's power fault level for an external regen resistor.
Units W
Range 0 to 62,000 W
Default Value 1000 W
Data Type Integer
See Also N/A
Start Version M_01-00-00-000
Fieldbus Index/Subindex Object Start Version
EtherCAT COE
and CANopen
3414h/0
M_01-00-00-000
Modbus 744 M_01-03-00-000
Description
Sets the regen resistor's power fault level for an external regen resistor (when REGEN.TYPE = -1).
Above this fault level, the regen resistor's PWM wil be 0 and a fault will be issued.