AKD User Guide | IL Parameters
IL.MFOLDR
General Information
Type R/O Parameter
Description Sets the motor foldback recovery time.
Units s
Range 0.1 to 65,535 s
Default Value Calculated from other foldback parameters.
Data Type Float
See Also Foldback
Start Version M_01-00-00-000
Fieldbus Index/Subindex Object Start Version
Modbus 466 M_01-03-00-000
Description
IL.MFOLDR sets the recovery time for the motor foldback algorithm. If 0 current is applied for at least the recov-
ery time duration, it is possible to apply motor peak current for the duration of IL.MFOLDD time.
The IL.MFOLDR value is automatically calculated from other foldback parameters.
Related Topics
11.3 Current Loop
480 Kollmorgen | December 2010

Table of Contents

Other manuals for Kollmorgen AKD series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kollmorgen AKD series and is the answer not in the manual?

Kollmorgen AKD series Specifications

General IconGeneral
Continuous CurrentUp to 180 A
Control ModesPosition, Velocity, Torque
Communication InterfacesEtherCAT, CANopen, Modbus TCP/IP
Feedback OptionsResolver, Encoder
Safety FeaturesSafe Torque Off (STO), Safe Stop 1 (SS1)
Protection FeaturesOvervoltage, Undervoltage, Overcurrent, Short Circuit, Overtemperature
Switching Frequency8 kHz, 16 kHz
Ambient Temperature0°C to 40°C
Operating Temperature0 - 40 °C (derating may apply)
Humidity5% to 95% non-condensing