EasyManua.ls Logo

Kollmorgen AKD series

Kollmorgen AKD series
906 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CAP0.EN, CAP1.EN
General Information
Type R/W Parameter
Description Enables or disables the related capture engine.
Units N/A
Range 0 to 1
Default Value 0
Data Type Boolean
See Also N/A
Start Version M_01-00-00-000
Fieldbus Index/Subindex Object Start Version
Modbus
56 CAP0.EN
82 CAP1.EN
M_01-03-00-000
Description
This parameter enables or disables the related capture engine. After each successful capture event, this param-
eter is reset to 0 and must be activated again for the next capture. Also note that CAP0.PLFB, CAP1.PLFB is
set to 0 when this parameter is set to 1.
0 = Disable
1 =Enable
Related Topics
8.11 Using Position Capture
AKD User Guide | CAP Parameters
Kollmorgen | December 2010 307