Page #307 background image
CAP0.EN, CAP1.EN
General Information
Type R/W Parameter
Description Enables or disables the related capture engine.
Units N/A
Range 0 to 1
Default Value 0
Data Type Boolean
See Also N/A
Start Version M_01-00-00-000
Fieldbus Index/Subindex Object Start Version
Modbus
56 CAP0.EN
82 CAP1.EN
M_01-03-00-000
Description
This parameter enables or disables the related capture engine. After each successful capture event, this param-
eter is reset to 0 and must be activated again for the next capture. Also note that CAP0.PLFB, CAP1.PLFB is
set to 0 when this parameter is set to 1.
0 = Disable
1 =Enable
Related Topics
8.11 Using Position Capture
AKD User Guide | CAP Parameters
Kollmorgen | December 2010 307

Table of Contents

Other manuals for Kollmorgen AKD series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kollmorgen AKD series and is the answer not in the manual?

Kollmorgen AKD series Specifications

General IconGeneral
Continuous CurrentUp to 180 A
Control ModesPosition, Velocity, Torque
Communication InterfacesEtherCAT, CANopen, Modbus TCP/IP
Feedback OptionsResolver, Encoder
Safety FeaturesSafe Torque Off (STO), Safe Stop 1 (SS1)
Protection FeaturesOvervoltage, Undervoltage, Overcurrent, Short Circuit, Overtemperature
Switching Frequency8 kHz, 16 kHz
Ambient Temperature0°C to 40°C
Operating Temperature0 - 40 °C (derating may apply)
Humidity5% to 95% non-condensing

Related product manuals