IL.MFOLDT
General Information
Type R/O Parameter
Description
Sets the motor foldback time constant of the exponential current drop (fold-
back).
Units s
Range 0.1 to 2,400 s
Default Value 10 s
Data Type Float
See Also Foldback
Start Version M_01-00-00-000
Fieldbus Index/Subindex Object Start Version
Modbus 468 M_01-03-00-000
Description
IL.MFOLDT sets the time constant of the exponential drop (foldback) of the current towards motor continuous
current.
Related Topics
11.3 Current Loop
AKD User Guide | IL Parameters
Kollmorgen | December 2010 481