AKD User Guide | MT Parameters and Commands
MT.EMERGMT
General Information
Type R/W Parameter
Description
Selects a motion task to be triggered after an emergency stop procedure;
active in opmode 2 (position) only.
Units N/A
Range 1 to 128
Default Value 0
Data Type N/A
See Also
MT.NUM , MT.P, MT.V, MT.CNTL, MT.ACC, MT.DEC, MT.TNUM,
MT.MTNEXT , MT.TNEXT, MT.SET , MT.LOAD
Start Version M_01-00-00-000
Fieldbus Index/Subindex Object Start Version
Modbus 540 M_01-03-00-000
Description
MT.EMERGMT selects the motion task to be triggered after an emergency stop procedure.
A value of –1 shows that no motion task must be started after a ramp-down procedure in a closed position loop
mode of operation.
Related Topics
12.2 Motion Tasks
522 Kollmorgen | December 2010

Table of Contents

Other manuals for Kollmorgen AKD series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kollmorgen AKD series and is the answer not in the manual?

Kollmorgen AKD series Specifications

General IconGeneral
Continuous CurrentUp to 180 A
Control ModesPosition, Velocity, Torque
Communication InterfacesEtherCAT, CANopen, Modbus TCP/IP
Feedback OptionsResolver, Encoder
Safety FeaturesSafe Torque Off (STO), Safe Stop 1 (SS1)
Protection FeaturesOvervoltage, Undervoltage, Overcurrent, Short Circuit, Overtemperature
Switching Frequency8 kHz, 16 kHz
Ambient Temperature0°C to 40°C
Operating Temperature0 - 40 °C (derating may apply)
Humidity5% to 95% non-condensing