EasyManuals Logo

Kollmorgen AKD series User Manual

Kollmorgen AKD series
906 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #410 background imageLoading...
Page #410 background image
AKD User Guide | FB1 Parameters
FB1.POLES
General Information
Type R/O Parameter
Description Reads the number of feedback poles.
Units N/A
Range 2 to 128
Default Value 2
Data Type Integer
See Also MOTOR.POLES
Start Version M_01-00-00-000
Fieldbus Index/Subindex Object Start Version
Modbus 302 M_01-03-00-000
Description
FB1.POLES sets the number of individual poles in the feedback device. This variable is used for the com-
mutation function, as well as for velocity feedback scaling, and represents the number of individual poles (not
pole pairs). The division value of motor poles (MOTOR.POLES) and feedback poles (FB1.POLES) must be an
integer when moving drive to enable, otherwise a fault is issued.
Related Topics
8.2 Feedback 1
410 Kollmorgen | December 2010

Table of Contents

Other manuals for Kollmorgen AKD series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kollmorgen AKD series and is the answer not in the manual?

Kollmorgen AKD series Specifications

General IconGeneral
Continuous CurrentUp to 180 A
Control ModesPosition, Velocity, Torque
Communication InterfacesEtherCAT, CANopen, Modbus TCP/IP
Feedback OptionsResolver, Encoder
Safety FeaturesSafe Torque Off (STO), Safe Stop 1 (SS1)
Protection FeaturesOvervoltage, Undervoltage, Overcurrent, Short Circuit, Overtemperature
Switching Frequency8 kHz, 16 kHz
Ambient Temperature0°C to 40°C
Operating Temperature0 - 40 °C (derating may apply)
Humidity5% to 95% non-condensing