AKD User Guide | IL Parameters
IL.KVFF
General Information
Type R/W
Description Current loops velocity feed-forward gain
Units N/A
Range 0 to 2
Default Value 0
Data Type Float
See Also IL.FF
Start Version M_01-00-00-000
Fieldbus Index/Subindex Object Start Version
Modbus 458 M_01-03-00-000
Description
This parameter sets the gain for the velocity loop feedforward. The nominal feedforward value can be multiplied
by this gain value.
This parameter is only used in position mode (DRV.OPMODE = 2).
Related Topics
11.3 Current Loop
476 Kollmorgen | December 2010

Table of Contents

Other manuals for Kollmorgen AKD series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kollmorgen AKD series and is the answer not in the manual?

Kollmorgen AKD series Specifications

General IconGeneral
Continuous CurrentUp to 180 A
Control ModesPosition, Velocity, Torque
Communication InterfacesEtherCAT, CANopen, Modbus TCP/IP
Feedback OptionsResolver, Encoder
Safety FeaturesSafe Torque Off (STO), Safe Stop 1 (SS1)
Protection FeaturesOvervoltage, Undervoltage, Overcurrent, Short Circuit, Overtemperature
Switching Frequency8 kHz, 16 kHz
Ambient Temperature0°C to 40°C
Operating Temperature0 - 40 °C (derating may apply)
Humidity5% to 95% non-condensing