EasyManua.ls Logo

Kollmorgen AKD series

Kollmorgen AKD series
906 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
AKD User Guide | VL Parameters
VL.FBFILTER
General Information
Type R/O Parameter
Description Filters VL.FB value; active in opmodes 1 (velocity) and 2 (position) only.
Units
Depends on UNIT.VROTARY or UNIT.VLINEAR
Rotary: rpm, rps, deg/s, (PIN/POUT)/s, rad/s
Linear: counts/s, mm/s, µm/s, (PIN/POUT)/s
Range N/A
Default Value N/A
Data Type Float
See Also VL.FB
Start Version M_01-00-00-000
Fieldbus Index/Subindex Object Start Version
EtherCAT COE
and CANopen
3407h/1 M_01-00-00-000
Modbus 858 M_01-03-00-000
Description
This parameter returns the same value as VL.FB, filtered through a 10 Hz filter.
Related Topics
11.4 Velocity Loop
634 Kollmorgen | December 2010

Table of Contents