VBUS.UVWTHRESH
General Information
Type NV Parameter
Description Sets voltage level for undervoltage warning.
Units Vdc
Range 0 to 900 Vdc
Default Value
10 volts above the default value of the under voltage fault threshold
(VBUS.UVFTHRESH). The default value of VBUS.UVFTHRESH is hard-
ware dependent.
Data Type U16
See Also VBUS.UVFTHRESH
Start Version M_01-00-00-000
Fieldbus Index/Subindex Object Start Version
Modbus 804 M_01-03-00-000
Description
If VBUS.VALUE value drops below VBUS.UVWTHRESH, then a warning is generated.
Related Topics
7.2 Regeneration
AKD User Guide | VBUS Parameters
Kollmorgen | December 2010 619

Table of Contents

Other manuals for Kollmorgen AKD series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kollmorgen AKD series and is the answer not in the manual?

Kollmorgen AKD series Specifications

General IconGeneral
Continuous CurrentUp to 180 A
Control ModesPosition, Velocity, Torque
Communication InterfacesEtherCAT, CANopen, Modbus TCP/IP
Feedback OptionsResolver, Encoder
Safety FeaturesSafe Torque Off (STO), Safe Stop 1 (SS1)
Protection FeaturesOvervoltage, Undervoltage, Overcurrent, Short Circuit, Overtemperature
Switching Frequency8 kHz, 16 kHz
Ambient Temperature0°C to 40°C
Operating Temperature0 - 40 °C (derating may apply)
Humidity5% to 95% non-condensing