AKD User Guide | DRV Parameters and Commands
DRV.SETUPREQLIST
General Information
Type R/O Parameters
Description
Reads the list of parameters that must be set before the drive can be ena-
bled.
Units N/A
Range N/A
Default Value N/A
Data Type N/A
See Also DRV.SETUPREQBITS, MOTOR.AUTOSET
Start Version M-00-00-64-000
Description
This parameter returns the list of parameters that must be set before the drive can be enabled and also whether or
not each one of those parameters is set. Only when all commands have value of 0 can the drive be enabled.
Please note that if MOTOR.AUTOSET is set to 1 (parameters automatically calculated from motor IDdata), then
all values in the list will be initialized from the feedback device. Otherwise, the parameters must be set manually.
Example
-->DRV.SETUPREQLIST
IL.KP 0
MOTOR.ICONT 0
MOTOR.IPEAK 0
MOTOR.POLES 0
-->
390 Kollmorgen | December 2010

Table of Contents

Other manuals for Kollmorgen AKD series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kollmorgen AKD series and is the answer not in the manual?

Kollmorgen AKD series Specifications

General IconGeneral
Continuous CurrentUp to 180 A
Control ModesPosition, Velocity, Torque
Communication InterfacesEtherCAT, CANopen, Modbus TCP/IP
Feedback OptionsResolver, Encoder
Safety FeaturesSafe Torque Off (STO), Safe Stop 1 (SS1)
Protection FeaturesOvervoltage, Undervoltage, Overcurrent, Short Circuit, Overtemperature
Switching Frequency8 kHz, 16 kHz
Ambient Temperature0°C to 40°C
Operating Temperature0 - 40 °C (derating may apply)
Humidity5% to 95% non-condensing