DOUT1.STATEU AND DOUT2.STATEU
General Information
Type R/W Parameter
Description Sets the state of the digital output node.
Units N/A
Range 0 to 1
Default Value 0
Data Type N/A
See Also N/A
Start Version M_01-01-01-000
Fieldbus Index/Subindex Object Start Version
Modbus
204 DOUT1.STATEU
214 DOUT2.STATEU
M_01-03-00-000
Description
DOUT1.STATEU and DOUT2.STATEU set the state of the digital output node as follows:
0 = deactivated
1 = activated
DOUT1.STATEU and DOUT2.STATEUare used when DOUTx.MODE = 0 (user mode).
Related Topics
10.1.4 Digital Outputs
AKD User Guide | DOUT Parameters