EasyManuals Logo

Kollmorgen AKD series User Manual

Kollmorgen AKD series
906 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #565 background imageLoading...
Page #565 background image
REC.DONE
General Information
Type R/O Parameter
Description Checks whether or not the recorder has finished recording.
Units N/A
Range 0 to 1
Default Value N/A
Data Type Boolean
See Also REC.ACTIVE, REC.OFF
Start Version M_01-00-00-000
Fieldbus Index/Subindex Object Start Version
Modbus 710 M_01-03-00-000
Description
REC.DONE indicates that the recorder has finished recording. This value is reset to 0 when the recorder trigger
is set. The drive also resets this value when the recording has finished or when REC.OFF is executed.
Related Topics
15 Scope
AKD User Guide | REC Parameters and Commands
Kollmorgen | December 2010 565

Table of Contents

Other manuals for Kollmorgen AKD series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kollmorgen AKD series and is the answer not in the manual?

Kollmorgen AKD series Specifications

General IconGeneral
Continuous CurrentUp to 180 A
Control ModesPosition, Velocity, Torque
Communication InterfacesEtherCAT, CANopen, Modbus TCP/IP
Feedback OptionsResolver, Encoder
Safety FeaturesSafe Torque Off (STO), Safe Stop 1 (SS1)
Protection FeaturesOvervoltage, Undervoltage, Overcurrent, Short Circuit, Overtemperature
Switching Frequency8 kHz, 16 kHz
Ambient Temperature0°C to 40°C
Operating Temperature0 - 40 °C (derating may apply)
Humidity5% to 95% non-condensing

Related product manuals