MOTOR.TEMPFAULT
General Information
Type NV Parameter
Description Sets the motor temperature fault level.
Units
Range 0 to 2,000,000,000
Default Value 0 = switched off
Data Type Integer
See Also MOTOR.TEMP
Start Version M_01-00-00-000
Fieldbus Index/Subindex Object Start Version
EtherCAT COE
and CANopen
3586h/0 M_01-00-00-000
Modbus 516 M_01-03-00-000
Description
This parameter is used to configure the motor temperature fault level as a resistance threshold of the motor PTC.
A zero value prevents any warning from being issued.
Related Topics
8.1 Motor
AKD User Guide | MOTOR Parameters