AKD User Guide | 8 Configuring Motor Settings
8.11.2.5 Setting the Pre-Condition Event: (CAP0.EVENT)
The Capture Pre-Condition Event gives the user more flexibility in setting what conditions must be present for the
Capture to trigger.
Event Options:
0 No precondition. Capture triggers as soon as the capture edge occurs.
1 Trigger Edge after precondition. Captures triggers only when the precondition occurs before
the capture edge occurs.
2 Trigger Edge while precondition = 1. Captures triggers only while the precondition is eval-
uated and is true while the capture edge occurs.
3 Trigger Edge while precondition = 0. Captures triggers only while the precondition is eval-
uated and is false while the capture edge occurs
8.11.2.6 Setting up a Pre-Condition for complex capture
Setting the Precondition Edge: (Terminal Command: CAP0.PREEDGE)
The pre-edge determines what input state change triggers the precondition. This feature operates the same as
the capture edge described above.
Setting the Pre-Condition Select: (Terminal Command: CAP0.PRESELECT)
The preselect chooses what input source will trigger the precondition (based on the preedge setting, and the pre-
filter setting). This feature operates the same as the capture source described above.
8.11.3 Related Parameters
CAP Parameters
78 Kollmorgen | December 2010

Table of Contents

Other manuals for Kollmorgen AKD series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kollmorgen AKD series and is the answer not in the manual?

Kollmorgen AKD series Specifications

General IconGeneral
Continuous CurrentUp to 180 A
Control ModesPosition, Velocity, Torque
Communication InterfacesEtherCAT, CANopen, Modbus TCP/IP
Feedback OptionsResolver, Encoder
Safety FeaturesSafe Torque Off (STO), Safe Stop 1 (SS1)
Protection FeaturesOvervoltage, Undervoltage, Overcurrent, Short Circuit, Overtemperature
Switching Frequency8 kHz, 16 kHz
Ambient Temperature0°C to 40°C
Operating Temperature0 - 40 °C (derating may apply)
Humidity5% to 95% non-condensing

Related product manuals