Input
Value
Description
40
Manually sets the type to resolver. This input sets the value of FB1.IDENTIFIED to 40.
If the feedback setting fails, FB1.IDENTIFIED is automatically set to 0 (no feedback
identified).
41
Manually sets the type to SFD. This input sets the value of FB1.IDENTIFIED to 41. If
the feedback setting fails, FB1.IDENTIFIED is automatically set to 0 (no feedback iden-
tified).
FB1.SELECTFeedback Types
Type Description
0 Unknown
10
Incremental encoder with A/B Quad, marker
pulse and Hall
11
Incremental encoder with A/B Quad, marker
pulse and no Hall
20 Sine Encoder , with marker pulse and Hall
21
Sine encoder , with marker pulse & No
Halls
30 EnDat 2.1 with Sine Cosine
31 EnDat 2.2
32 BiSS with Sine Cosine
33 HIPERFACE
34 BiSS Mode C Renishaw
40 Resolver
41 SFD
Related Topics
8.2 Feedback 1
AKD User Guide | FB1 Parameters
Kollmorgen | December 2010 415

Table of Contents

Other manuals for Kollmorgen AKD series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kollmorgen AKD series and is the answer not in the manual?

Kollmorgen AKD series Specifications

General IconGeneral
Continuous CurrentUp to 180 A
Control ModesPosition, Velocity, Torque
Communication InterfacesEtherCAT, CANopen, Modbus TCP/IP
Feedback OptionsResolver, Encoder
Safety FeaturesSafe Torque Off (STO), Safe Stop 1 (SS1)
Protection FeaturesOvervoltage, Undervoltage, Overcurrent, Short Circuit, Overtemperature
Switching Frequency8 kHz, 16 kHz
Ambient Temperature0°C to 40°C
Operating Temperature0 - 40 °C (derating may apply)
Humidity5% to 95% non-condensing