3 Function diagrams
3.5 PROFIdrive
Fig. 3-31 2441 – STW1 control word interconnection (p2038 = 2)
- 2441 -
Function diagram
87654321
fp_2441_54_eng.vsd
DO: VECTOR
S120/S150/G130/G150
27.06.13 V04.07.00
PROFIdrive - STW1 control word interconnection (p2038 = 2)
<1> Used in telegram 20.
STW1.0
STW1.1
STW1.2
STW1.3
STW1.4
STW1.5
STW1.6
STW1.8
STW1.9
STW1.11
STW1.12
STW1.13
STW1.14
STW1.15
STW1.7
STW1.10
p0848[0] = r2090.2
p0852[0] = r2090.3
p1140[0] = r2090.4
p1141[0] = r2090.5
p1142[0] = r2090.6
p2103[0] = r2090.7
-
-
p0854[0] = r2090.10
p1113[0] = r2090.11
-
-
p0810[0] = 2090.15
p0840[0] = r2090.0
p0844[0] = r2090.1
= ON (pulses can be enabled)
0 = OFF1 (braking with ramp-function generator, then pulse suppression & ready for switching on)
1 = No OFF2 (enable is possible) <3>
0 = OFF2 (immediate pulse suppression and switching on inhibited)
1 = No OFF3 (enable possible) <3>
0 = OFF3 (braking with the OFF3 ramp p1135, then pulse suppression and switching on inhibited)
1 = Enable operation (pulses can be enabled)
0 = Inhibit operation (suppress pulses)
1 = Operating condition (the ramp-function generator can be enabled)
0 = Inhibit ramp-function generator (set the ramp-function generator output to zero)
1 = Enable the ramp-function generator
0 = Stop the ramp-function generator (freeze the ramp-function generator output)
1 = Enable setpoint
0 = Inhibit setpoint (set the ramp-function generator input to zero)
= 1. Acknowledge faults
Reserved
Reserved
1 = Control via PLC
1 = Direction reversal
Reserved
1 = Command Data Set selection CDS bit 0
Reserved
[2501.3]
[2501.3]
[2501.3]
[2501.3]
[2501.3]
[2546.1]
-
-
[2501.3]
[2505.3]
-
-
-
[2501.3]
[2501.3]
Signal targets for STW1 in Interface Mode VIK-NAMUR (p2038 = 2)
[2610]
[2610]
[3060] [3070] [3080]
[3060] [3070]
[3060] [3070] [3080]
[8060]
-
-
[2501]
[3040]
-
-
[8560]
[2610]
[2610]
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Signal
Interconnection
parameters
Meaning
[Function diagram]
internal control word
[Function diagram]
signal target
Inverted
<2> STW1.10 must be set to ensure that the drive object accepts the process data (PZD).
<2>
<1>
PROFIdrive sampling time
<3> OC = Operating condition.
<4> Interconnection is not disabled.
<4>
1 = Unconditionally open the holding brake p0855[0] = r2090.12 [2501.3] [2701]