2 Parameters
2.2 List of parameters
SINAMICS G130/G150
574 List Manual (LH2), 04/2014, A5E03263479A
Description: Displays the current actual value from current transducer (CT) 1 at the 10 V input of the Voltage Sensing Module
(VSM).
Dependency: Refer to: p3670
Note: The CT for phase 1 is connected at terminals X520.1 and X520.2 of the VSM.
Description: Displays the current actual value from current transducer (CT) 2 at the 10 V input of the Voltage Sensing Module
(VSM).
Dependency: Refer to: p3670
Note: The CT for phase 2 is connected at terminals X520.3 and X520.4 of the VSM.
Description: Displays the actual value of the voltage measured at the 10 V input 1 of the Voltage Sensing Modules (VSM).
Dependency: Refer to: p3670
Note: 10 V input 1: Terminals X520.1 and X520.2
Description: Displays the actual value of the voltage measured at the 10 V input 2 of the Voltage Sensing Modules (VSM).
Dependency: Refer to: p3670
Note: 10 V input 2: Terminals X520.3 and X520.4
r3671[0...n] CO: VSM 10 V input CT 1 actual value / VSM CT 1 I_act
VECTOR_G Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: p0150 Func. diagram: 9880
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: - Scaling: p2002 Expert list: 1
Min Max Factory setting
- [A] - [A] - [A]
r3672[0...n] CO: VSM 10 V input CT 2 actual value / VSM CT 2 I_act
VECTOR_G Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: p0150 Func. diagram: 9880
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: - Scaling: p2002 Expert list: 1
Min Max Factory setting
- [A] - [A] - [A]
r3673[0...n] CO: VSM 10 V input 1 actual value / VSM inp 1 U_act
VECTOR_G Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: p0150 Func. diagram: 9880
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: - Scaling: p2001 Expert list: 1
Min Max Factory setting
- [V] - [V] - [V]
r3674[0...n] CO: VSM 10 V input 2 actual value / VSM inp 2 U_act
VECTOR_G Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: p0150 Func. diagram: 9880
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: - Scaling: p2001 Expert list: 1
Min Max Factory setting
- [V] - [V] - [V]