2 Parameters
2.2 List of parameters
SINAMICS G130/G150
596 List Manual (LH2), 04/2014, A5E03263479A
Dependency: Refer to: r3925
Note: The parameter is a copy of p1959.
Description: For service personnel only.
Description: Displays the status word for the drive unit.
Description: Displays the BICO interconnections that have been parameterized in the complete (overall) topology.
The counter is incremented by one for each modified BICO interconnection.
Dependency: Refer to: r3978, r3979
Bit field: Bit Signal name 1 signal 0 signal FP
00 Encoder test active Yes No -
01 Saturation characteristic identification Yes No -
02 Moment of inertia identification Yes No -
03 Re-calculates the speed controller
parameters
Yes No -
04 Speed controller optimization (vibration test) Yes No -
05 q leakage inductance ident. (for current
controller adaptation)
Yes No -
11 Do not change the controller parameters
during the measurement
Yes No -
12 Measurement shortened Yes No -
13 After measurement direct transition into
operation
Yes No -
p3950 Service parameter / Serv par
CU_G130_DP,
CU_G130_PN,
CU_G150_DP,
CU_G150_PN
Can be changed: C1, U, T Calculated: - Access level: 3
Data type: Unsigned16 Dyn. index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
r3974 Drive unit status word / Drv_unit ZSW
CU_G130_DP,
CU_G130_PN,
CU_G150_DP,
CU_G150_PN
Can be changed: - Calculated: - Access level: 1
Data type: Unsigned32 Dyn. index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 Software reset active Yes No -
01 Writing of parameters disabled as
parameter save in progress
Yes No -
02 Writing of parameters disabled as macro is
running
Yes No -
r3977 BICO counter topology / BICO counter topo
CU_G130_DP,
CU_G130_PN,
CU_G150_DP,
CU_G150_PN
Can be changed: - Calculated: - Access level: 4
Data type: Unsigned32 Dyn. index: - Func. diagram: -
P-Group: Commands Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -