SINAMICS G130/G150
List Manual (LH2), 04/2014, A5E03263479A
865
2 Parameters
2.2 List of parameters
Description: Displays the parameters whose parameter would have to be changed during a units changeover.
Description: Displays the number of BICO interconnections (signal sinks).
Dependency: Refer to: r9482, r9483
Note: The selected BICO interconnections should be entered into r9482 and r9483.
Description: Displays the signal sinks (binector/connector inputs, BI/CI parameters).
The number of BICO interconnections is displayed in r9481.
Dependency: Refer to: r9481, r9483
Note: The list is sorted according to signal sources and is structured as follows:
r9842[0]: Interconnection 1 (signal sink, BICO coded), r9843[0]: Interconnection 1 (signal source, BICO coded)
r9842[1]: Interconnection 2 (signal sink, BICO coded), r9843[1]: Interconnection 2 (signal source, BICO coded)
...
Description: Displays the signal sources (binector/connector outputs, BO/CO parameters).
The number of BICO interconnections is displayed in r9481.
Dependency: Refer to: r9481, r9482
Note: The list is sorted according to signal sources and is structured as follows:
r9842[0]: Interconnection 1 (signal sink, BICO coded), r9843[0]: Interconnection 1 (signal source, BICO coded)
r9842[1]: Interconnection 2 (signal sink, BICO coded), r9843[1]: Interconnection 2 (signal source, BICO coded)
...
r9451[0...29] Units changeover adapted parameters / Unit_chngov par
B_INF, ENC,
VECTOR_G
Can be changed: - Calculated: - Access level: 1
Data type: Unsigned32 Dyn. index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
r9481 Number of BICO interconnections / BICO count
B_INF, CU_G130_DP,
CU_G130_PN,
CU_G150_DP,
CU_G150_PN, ENC,
TB30, TM150, TM31,
TM54F_MA,
TM54F_SL,
VECTOR_G
Can be changed: - Calculated: - Access level: 3
Data type: Unsigned16 Dyn. index: - Func. diagram: -
P-Group: Commands Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 0
Min Max Factory setting
- - -
r9482[0...n] BICO interconnections BI/CI parameters / BICO BI/CI par
B_INF, CU_G130_DP,
CU_G130_PN,
CU_G150_DP,
CU_G150_PN, ENC,
TB30, TM150, TM31,
TM54F_MA,
TM54F_SL,
VECTOR_G
Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dyn. index: r9481 Func. diagram: -
P-Group: Commands Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 0
Min Max Factory setting
- - -
r9483[0...n] BICO interconnections BO/CO parameters / BICO BO/CO par
B_INF, CU_G130_DP,
CU_G130_PN,
CU_G150_DP,
CU_G150_PN, ENC,
TB30, TM150, TM31,
TM54F_MA,
TM54F_SL,
VECTOR_G
Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dyn. index: r9481 Func. diagram: -
P-Group: Commands Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 0
Min Max Factory setting
- - -