2 Parameters
2.2 List of parameters
SINAMICS G130/G150
94 List Manual (LH2), 04/2014, A5E03263479A
Recommend.: After inserting a component, before activating, first wait for Alarm A01317.
Dependency: Refer to: r0156
Description: Displays the "active" or "inactive" state of a Voltage Sensing Module (VSM).
Value: 0: Component inactive
1: Component active
Dependency: Refer to: p0155
Description: Displays the version of the EEPROM data for the DRIVE-CLiQ Hub Module.
Note: Example:
The value 1010100 should be interpreted as V01.01.01.00.
Description: Displays the version of the EEPROM data of the Terminal Module.
Dependency: Refer to: r0127, r0147
Note: Example:
The value 1010100 should be interpreted as V01.01.01.00.
Description: Displays the version of the EEPROM data of the Voltage Sensing Module (VSM).
Note: Example:
The value 1010100 should be interpreted as V01.01.01.00.
r0156[0...n] Voltage Sensing Module active/inactive / VSM act/inact
VECTOR_G Can be changed: - Calculated: - Access level: 2
Data type: Integer16 Dyn. index: p0150 Func. diagram: -
P-Group: Data sets Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 1 -
r0157 DRIVE-CLiQ Hub Module EEPROM data version / Hub EEPROM version
HUB Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dyn. index: - Func. diagram: -
P-Group: Terminals Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
r0157 Terminal Module EEPROM data version / TM EEPROM version
TM150, TM31,
TM54F_MA,
TM54F_SL
Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dyn. index: - Func. diagram: -
P-Group: Terminals Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
r0157[0...n] Voltage Sensing Module EEPROM data version / VSM EEPROM version
VECTOR_G Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dyn. index: p0150 Func. diagram: -
P-Group: Encoder Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -