2 Parameters
2.2 List of parameters
SINAMICS G130/G150
232 List Manual (LH2), 04/2014, A5E03263479A
Dependency: Refer to: p0358, r0380
Description: Factor to evaluate the damping inductance quadrature to the rotor axis (q axis).
Dependency: Refer to: p0359, r0381
Description: Factor to evaluate the damping resistance in the direction of the rotor axis (d axis).
Dependency: Refer to: p0354, r0374
Description: Factor to evaluate the damping resistance quadrature to the rotor axis (q axis).
Dependency: Refer to: p0355, r0375
Description: Sets the digital input used for the function "central measuring probe evaluation".
p0680[0]: Digital input, measuring probe 1
p0680[1]: Digital input, measuring probe 2
...
p0680[7]: Digital input, measuring probe 8
Value: 0: No meas probe
1: DI/DO 9 (X122.10/X121.8)
2: DI/DO 10 (X122.12/X121.10)
3: DI/DO 11 (X122.13/X121.11)
4: DI/DO 13 (X132.10/X131.2)
5: DI/DO 14 (X132.12/X131.4)
6: DI/DO 15 (X132.13/X131.5)
7: DI/DO 8 (X122.9/X121.7)
8: DI/DO 12 (X132.9/X131.1)
Dependency: Refer to: p0728
p0658[0...n] Motor damping inductance q axis scaling / Mot L_damp q scal
VECTOR_G Can be changed: C2(3), U, T Calculated: CALC_MOD_EQU Access level: 4
Data type: FloatingPoint32 Dyn. index: MDS, p0130 Func. diagram: 6727
P-Group: Motor Units group: - Unit selection: -
Not for motor type: ASM, PEM, REL Scaling: - Expert list: 1
Min Max Factory setting
10.0 [%] 300.0 [%] 100.0 [%]
p0659[0...n] Motor damping resistance d axis scaling / Mot R_damp d scal
VECTOR_G Can be changed: C2(3), U, T Calculated: CALC_MOD_EQU Access level: 4
Data type: FloatingPoint32 Dyn. index: MDS, p0130 Func. diagram: 6727
P-Group: Motor Units group: - Unit selection: -
Not for motor type: ASM, PEM, REL Scaling: - Expert list: 1
Min Max Factory setting
10.0 [%] 300.0 [%] 100.0 [%]
p0660[0...n] Motor damping resistance q axis scaling / Mot R_damp q scal
VECTOR_G Can be changed: C2(3), U, T Calculated: CALC_MOD_EQU Access level: 4
Data type: FloatingPoint32 Dyn. index: MDS, p0130 Func. diagram: 6727
P-Group: Motor Units group: - Unit selection: -
Not for motor type: ASM, PEM, REL Scaling: - Expert list: 1
Min Max Factory setting
10.0 [%] 300.0 [%] 100.0 [%]
p0680[0...7] Central measuring probe input terminal / Cen meas inp
CU_G130_DP,
CU_G130_PN,
CU_G150_DP,
CU_G150_PN
Can be changed: U, T Calculated: - Access level: 3
Data type: Integer16 Dyn. index: - Func. diagram: -
P-Group: Encoder Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 8 0