SINAMICS G130/G150
List Manual (LH2), 04/2014, A5E03263479A
681
2 Parameters
2.2 List of parameters
Description: Sets the time slice cycle in which the function generator is called.
Description: Sets the scaling for the amplitude of the signal waveforms for all output channels.
The value can be changed while the function generator is running.
Description: Sets the scaling for the amplitude of the signal waveforms separately for each output channel.
The value cannot be changed while the function generator is running.
Index: [0] = First drive for connection
[1] = Second drive for connection
[2] = Third drive for connection
Description: Sets the scaling for the offset of the signal waveforms separately for each output channel.
The value cannot be changed while the function generator is running.
Index: [0] = First drive for connection
[1] = Second drive for connection
[2] = Third drive for connection
p4830 Function generator time slice cycle / FG time slice
CU_G130_DP,
CU_G130_PN,
CU_G150_DP,
CU_G150_PN
Can be changed: U, T Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: - Func. diagram: -
P-Group: Trace and function generator Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 0
Min Max Factory setting
0.03125 [ms] 2.00000 [ms] 0.12500 [ms]
p4831 Function generator amplitude scaling / FG amplitude scal
CU_G130_DP,
CU_G130_PN,
CU_G150_DP,
CU_G150_PN
Can be changed: U, T Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: - Func. diagram: -
P-Group: Trace and function generator Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 0
Min Max Factory setting
0.00000 [%] 200.00000 [%] 100.00000 [%]
p4832[0...2] Function generator amplitude scaling / FG amplitude scal
CU_G130_DP,
CU_G130_PN,
CU_G150_DP,
CU_G150_PN
Can be changed: U, T Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: - Func. diagram: -
P-Group: Trace and function generator Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 0
Min Max Factory setting
-340.28235E36 [%] 340.28235E36 [%] 100.00000 [%]
p4833[0...2] Function generator offset scaling / FG offset scal
CU_G130_DP,
CU_G130_PN,
CU_G150_DP,
CU_G150_PN
Can be changed: U, T Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: - Func. diagram: -
P-Group: Trace and function generator Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 0
Min Max Factory setting
-340.28235E36 [%] 340.28235E36 [%] 100.00000 [%]