SINAMICS G130/G150
List Manual (LH2), 04/2014, A5E03263479A
629
2 Parameters
2.2 List of parameters
For sensor type "KTY84" (p4100 = 2), the following applies:
If the fault threshold (p4102[1]) is exceeded before the delay time has expired, then fault F35207 is immediately
output.
For sensor type "PTC thermistor" (p4100 = 1), the following applies:
- Alarm and fault threshold simultaneously respond. The fault is only issued after the delay time has expired.
Dependency: Refer to: r4104
Warning: Fault F35207 only causes the drive to be shut down if there is at least one BICO interconnection between the drive
and TM31.
Note: With p4103 = 0 ms, the timer is de-activated and only the fault threshold is effective.
Description: Display and binector output for the status for the Terminal Module 150 (TM150).
Dependency: Refer to: p4102, p4103, r4105, p4118
Description: Display and binector output for the status for the Terminal Module 31 (TM31).
Dependency: Refer to: p4102
r4104.0...23 BO: TM150 temperature evaluation status / TM150 temp status
TM150 Can be changed: - Calculated: - Access level: 1
Data type: Unsigned32 Dyn. index: - Func. diagram: 9626, 9627
P-Group: Terminals Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 Channel 0 alarm present Yes No 9626
01 Channel 0 fault present Yes No 9626
02 Channel 1 alarm present Yes No 9626
03 Channel 1 fault present Yes No 9626
04 Channel 2 alarm present Yes No 9626
05 Channel 2 fault present Yes No 9626
06 Channel 3 alarm present Yes No 9626
07 Channel 3 fault present Yes No 9626
08 Channel 4 alarm present Yes No 9626
09 Channel 4 fault present Yes No 9626
10 Channel 5 alarm present Yes No 9626
11 Channel 5 fault present Yes No 9626
12 Channel 6 alarm present Yes No 9627
13 Channel 6 fault present Yes No 9627
14 Channel 7 alarm present Yes No 9627
15 Channel 7 fault present Yes No 9627
16 Channel 8 alarm present Yes No 9627
17 Channel 8 fault present Yes No 9627
18 Channel 9 alarm present Yes No 9627
19 Channel 9 fault present Yes No 9627
20 Channel 10 alarm present Yes No 9627
21 Channel 10 fault present Yes No 9627
22 Channel 11 alarm present Yes No 9627
23 Channel 11 fault present Yes No 9627
r4104.0...1 BO: TM31 temperature evaluation status / TM31 temp status
TM31 Can be changed: - Calculated: - Access level: 1
Data type: Unsigned16 Dyn. index: - Func. diagram: 9549, 9576
P-Group: Terminals Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 Alarm is present Yes No -
01 Fault is present Yes No -